Specifications
- Capacity (Model AC-50K): 22,700 kg / 50,000 lb
- Capacity (Model AC-100K): 45,000 kg / 100,000 lb
- Cell Type: Analog compression load cell
- Rated Output: 2 mV/V at Rated Capacity
- Output Resistance: 1005±5
- Input Resistance: 1150±50
- Cable Length: 15.2 m / 50 ft
- Protection Class: IP69K
- Construction: Stainless steel load cells with plated alloy steel anti-rotation cups
- Mounting: Extra robust upper and lower receiver cups
- Options: Universal analog junction box, transient protection junction box, pull box, load cell retainer plate, load cell cups and mounting hardware for RC3
- Accuracy Class: 4,000 n. OIML / 10,000 NTEP
- Warranty: 1 year
- Minimum Dead Load: 0%Ln
- Service Load: 120%Ln
- Safe Load Limit: 200% Rated Capacity
- Total Error: < ±0.017%Sn
- Repeatability Error: < ±0.015%Sn
- Temperature Effect on Zero: < ±0.01%Sn/5 °C
- Temperature Effect on Sensitivity: < ±0.006 %Sn/5 °C
- Creep Error (30 minutes): < ±0.016 %Sn
- Temperature Compensation: -10˚C to +40˚C
- Temperature Limits: -50˚C to +60˚C (OIML and NTEP certified up to +40˚)
- Nominal Sensitivity: 2mV/V
- Nominal Input Voltage: 10V
- Maximum Input Voltage: 15V
- Input Impedance: 1150±50Ω
- Output Impedance: 1005±5Ω
- No Load Output: ±2%Sn
- Insulation Resistance: > 5000 Ω
- Maximum Deflection: 0.6-1mm
- NTEP Certification Number: 17-123
- OIML Certification Number: 2000-A-GB1-18.03
Features
- Conversion kits for PDX and MTX load cells
- Anti-rotation system with top and bottom cups
- Stainless steel IP69K load cell protection rating
- iSite Cloud-based remote monitoring
- Interchangeable with Mettler Toledo™ PowerCell® digital load cells
- Both PDX and MTX conversion kits available
- Stainless steel, environmentally-sealed load cells for years of trouble-free service
- High-capacity vehicle weighing
- Heavy-duty compression load cells with self-centering column
- OIML and NTEP certified for international use
- Hermetically-welded, protection class IP69K load cells
- Rugged enclosure for protection from the elements
- Heavy-duty cables to eliminate electromagnetic interference (50 ft /15.2 m cable per load cell)
- Extra-robust upper and lower cups for optimal weighbridge support and stability
- Durable stainless steel construction that is built to last
- Machined precision and precipitation hardened
PRODUCT OPTIONS
Part Number | Size | Type | Capacity |
---|---|---|---|
AC-100K-MTX-10 | – | Retrofit Kits | 10 Cell |
AC-100K-MTX-12 | – | Retrofit Kits | 12 Cell |
AC-100K-MTX-4 | – | Retrofit Kits | 4 Cell |
AC-100K-MTX-6 | – | Retrofit Kits | 6 Cell |
AC-100K-MTX-8 | – | Retrofit Kits | 8 Cell |
AC-100K-PDX-10 | – | Retrofit Kits | 10 Cell |
AC-100K-PDX-12 | – | Retrofit Kits | 12 Cell |
AC-100K-PDX-4 | – | Retrofit Kits | 4 Cell |
AC-100K-PDX-6 | – | Retrofit Kits | 6 Cell |
AC-100K-PDX-8 | – | Retrofit Kits | 8 Cell |
AC-50K-MTX-10 | – | Retrofit Kits | 10 Cell |
AC-50K-MTX-12 | – | Retrofit Kits | 12 Cell |
AC-50K-MTX-4 | – | Retrofit Kits | 4 Cell |
AC-50K-MTX-6 | – | Retrofit Kits | 6 Cell |
AC-50K-MTX-8 | – | Retrofit Kits | 8 Cell |
AC-50K-PDX-10 | – | Retrofit Kits | 10 Cell |
AC-50K-PDX-12 | – | Retrofit Kits | 12 Cell |
AC-50K-PDX-4 | – | Retrofit Kits | 4 Cell |
AC-50K-PDX-6 | – | Retrofit Kits | 6 Cell |
AC-50K-PDX-8 | – | Retrofit Kits | 8 Cell |