Specifications
- Power Requirements: 100 to 240 VAC (50/60 Hz) at 0.4A Max.
- Enclosure Type: Stainless steel wall or desk-mount
- Enclosure Size: 10.8 in W x 3.2 in D x 8.3 in H / 275 mm W x 80 mm D x 210 mm H
- Weight: 9.2 lb / 4.2 kg (Size and Weight does not include mounting bracket stand)
- Operating Temperature: 14º to 104º F (-10º to +40º C)
- Operating Humidity: 90% non-condensing (maximum)
- Display: 240 x 64 pixel (5 in W x 1.33 in H / 127 mm W x 34 mm H) monochrome graphics LCD with white LED backlight
- Annunciators: Zero, ID, mem, stable, accum, max, over, under, accept, 16 preset weight comparators
- Keypad: 60 key color-coded keypad with QWERTY keys plus four soft keys and 13 function keys
- Transducer Excitation: 12VDC
- Signal Input Range: 1.0 mV min. to 40 mV max. (with dead load boost)
- Scales: 1 each standard, 3 each with optional 225-DS dual scale input board
- Number of Load Cells: 14 each, 350 OHM minimum resistance
- Load Cell Cable Length: 1,500 feet maximum with sense lines – 30 feet maximum without sense lines
- Division Value Commercial: 1, 2, or 5 x 10, 1, 0.1, 0.01, 0.001 and 0.0001
- Division Value Non-Commercial: 0 to 99
- Sensitivity – Non-Commercial: 0.15 uV/e
- Sensitivity – NTEP: 0.3uV/e (Class III/IIIL)
- Sensitivity – Canada: 0.3uV/e (Class III/IIIHD)
- Sensitivity – OIML: 0.7 uV/e (Class III)
- Scale Divisions – Non-Commercial: 100 to 240,000
- Scale Divisions – NTEP: 100 to 10,000 (Class III/IIIL)
- Scale Divisions – Canada: 100 to 10,000 (Class III/IIIHD)
- Scale Divisions – OIML: 100 to 10,000 (Class III)
- Internal Resolution: 1 part in 16,777,216
- Tare Capacity: Six digits (999,999)
- Sample Rate: 1 to 100 samples per second, selectable
- Auto Zero Range: 0.5 or 1 through 9 divisions
- Weighing Units: Tons, Pounds, Ounces, Tonnes (Metric Tons), Kilograms, Grams, Custom
- Standard I/O: 4 each serial I/O ports configured as: 3 each bi-directional RS-232 ports or 2 each 20mA output-only ports, 1 each USB-B port, 1 each bi-directional 20mA port, 8 each remote isolated inputs, and 16 each remote isolated outputs
- IDs: 200 permanent truck storage IDs and 200 temporary truck storage IDs
Features
- 200 ID’s
- 240 x 64 Pixel LCD
- 4 Soft Keys
- Alphanumeric Keypad
- Electronic Tally Roll
- IP66 Enclosure Rating
- Navigation Keys
- NTEP Legal for Trade
- OIML Certified
- Powers up to 14 Load Cells
Part Number | Size | Type | Capacity |
---|---|---|---|
225ICANP | – | – | – |
225 | – | – | – |
225D | – | – | – |
225DEU | – | – | – |
225DUK | – | – | – |
225EU | – | – | – |
225ICANG | – | – | – |
225UK | – | – | – |